Moeller-era IZM20, IZM26, IZM32 and IZM40 — built on the Masterpact M and just as obsolete — and Eaton's own IZMX16 and IZMX40. Repaired, rebuilt and injection-tested, with modern trip units engineered into the older frames.

  • RangesIZM20–40 · IZMX16 / IZMX40
  • Trip unitsIZM-DT · PXR · retrofits
  • Turnaround24–48 hrs once quoted
  • Warranty12 months

The range

The Masterpact in Moeller clothing

The Moeller IZM20 to IZM40 series is a Merlin Gerin Masterpact M with Moeller badging and its own trip units. That matters for two reasons. The mechanism, contacts, coils and charging motor are Masterpact M parts, which means the donor stock and re-machining capability we hold for the M range applies directly. And the trip electronics are as obsolete as the STR units they replaced, so a dead trip unit on an IZM32 gets the same answer: a modern unit engineered into the original frame, set to the original characteristic, proved by injection test. The breaker stays in its cell — no adapter plate, no new cradle, no board project.

Eaton's later IZMX16 and IZMX40 are current and their faults are the everyday ones: coils, motor operators, contact wear, cradle clusters and PXR trip-unit connectors. All repaired in the workshop.

IZM — what typically fails
IZM20 / 26 / 32 / 40 (Moeller)Obsolete trip electronics, hardened mechanism grease, closing coil, charging motor; spares discontinued — repaired from Masterpact M donor stock and re-machined parts
IZMX16 / IZMX40 (Eaton)Coils and motor operator, PXR connector faults, contact erosion on high-duty units, cradle cluster contacts
Cradles (all)Cluster contact erosion and overheating, racking mechanism wear, position switches

FAQs

Frequently asked

Eaton says the IZM32 is obsolete and quotes an IZMX retrofit. Is repair an option?

Yes, and usually the cheaper one. The IZM32 is a Masterpact M underneath; its mechanism and contacts are rebuilt from the same donor stock and re-machining we use for the M range, and a dead trip unit is replaced with a modern unit inside the original frame. An IZMX retrofit changes the cradle and the wiring — a board project rather than a breaker repair.

Can you fit a modern trip unit to an IZM26?

Yes. The unit is engineered into the frame, set to reproduce the original characteristic — or to the settings you specify — and injection-tested at those settings before dispatch. See protection unit replacement.

What about older Moeller and Klöckner-Moeller breakers?

Send the nameplate. Several of the older ranges are supportable from donor stock and re-machining; we'll tell you quickly whether yours is one of them. See obsolete circuit breaker repair.

Get started

Tell us about the breaker

Make, model and rating from the nameplate, plus a description of the fault. We'll come back with a clear recommendation and a fixed price — usually the same working day.

Photos help us quote faster — email pictures of the breaker and its nameplate to info@circuitbreakerrepair.co.uk with your name, or reply to our confirmation.

We reply the same working day. Site down? Call 01977 253063 — out of hours 07496 013884.

Call an engineer Get a quote