Schneider Electric · TeSys F

Schneider LC1F Contactor Repair

TeSys F contactors from LC1F115 to LC1F2100 overhauled with new contact sets, LX1F coils, pole carriers and auxiliaries, and tested for pick-up, drop-out and contact resistance per pole. The generator, compressor and wind-turbine contactor we rebuild more than any other — for UK sites and, by air freight, for US customers.

  • FramesLC1F115 – LC1F2100
  • CoilsLX1FF – LX1FL, AC and DC
  • Turnaround2–5 working days
  • Warranty12 months

The range

Every LC1F frame, every wearing part

The TeSys F range is the high-current contactor in a large share of European-built machinery, standby generator sets and wind-turbine converter cabinets. It is well made and it wears in well-understood ways: the silver-alloy main contacts erode and pit until the poles run hot or weld; the contact springs lose pressure; the LX1F coil overheats in a warm cabinet or fails on a control-supply transient; the magnet faces pick up debris and the contactor chatters; and the LA1/LADN auxiliary blocks that feed the controller go intermittent.

A new LC1F630 or LC1F800 is a four-figure item on a lead time. An overhaul replaces every wearing part as a set — contacts, springs, coil where marginal, auxiliaries, arc chutes where eroded — on a frame that already matches the enclosure, the busbar drilling and the control wiring. The contactor is then tested as a unit, not just checked for closure, and the results go on the certificate against its serial number.

Schneider TeSys F LC1F780 with arc chutes removed showing six restored pole assemblies and re-plated contacts
LC1F780 after overhaul: pole assemblies restored, contacts re-plated
LC1F frames and overhaul items
LC1F115 · F150 · F185Contact sets, LX1FF/FG coils, auxiliaries; below F150 a new unit is often the better call — we'll say
LC1F225 · F265 · F330Contact sets and springs, LX1FH coils, arc chutes, auxiliary blocks
LC1F400 · F500 · F630Contact sets, LX1FJ/FK coils, pole carriers from donor stock, arc chutes, terminations
LC1F780 · F800 · F1250Contact sets, LX1FL coils, pole carriers, magnet and shading rings, arc chutes
LC1F1400 · F1700 · F2100Full strip and rebuild; contact sets, coils, magnet assembly, terminations

Testing

Proved, not just closed

Pick-up voltage at the bottom of the coil's tolerance band, so the contactor closes when the control supply sags. Drop-out voltage, so it releases when commanded. Contact resistance per pole with a micro-ohmmeter, balanced across the three poles, so they run cool at full current. Coil current and insulation resistance. Mechanical operation for chatter and bounce, and every auxiliary block proved in both positions. It is written on the certificate for the site engineer, with the parts fitted.

Test record — per contactor
Pick-up voltageAt or below lower coil tolerance limit
Drop-out voltageWithin the manufacturer's band
Contact resistanceμΩ / mΩ per pole, balanced
Insulation resistancePole-to-pole, pole-to-earth
CoilResistance and current at rated voltage
AuxiliariesEvery NO/NC proved

FAQs

Frequently asked

How much does an LC1F overhaul cost against a new contactor?

Quoted after strip-down, but the working rule on the F400 and above is a third to a half of a new unit, and less where only contacts and a coil are needed. Diagnosis is quoted up front. On the small frames — F115 and F150 — a new contactor is often the better answer and we'll tell you.

My LC1F keeps welding. Will an overhaul fix it?

The overhaul replaces the welded contacts and any heat-damaged carriers. Repeated welding on the same duty is an application problem — an undersized frame for the inrush, a coil supply that dips under load and lets the contactor chatter, or the wrong utilisation category — and the strip-down report will say so, so it doesn't happen again.

Do you hold exchange stock for LC1F?

For fleet customers, yes — overhauled units held against your frame sizes and dispatched the day a failure is reported. See service exchange.

Do you repair LC1F contactors for US customers?

Yes, continuously. LC1F units travel between our Yorkshire workshop and US customers by air freight with the export paperwork handled. See repair for US operators.

Get started

Tell us about the breaker

Make, model and rating from the nameplate, plus a description of the fault. We'll come back with a clear recommendation and a fixed price — usually the same working day.

Photos help us quote faster — email pictures of the breaker and its nameplate to info@circuitbreakerrepair.co.uk with your name, or reply to our confirmation.

We reply the same working day. Site down? Call 01977 253063 — out of hours 07496 013884.

Call an engineer Get a quote